首页 / 院系成果 / 成果详情页

Development and validation of the coronary heart disease scale under the system of quality of life instruments for chronic diseases QLICD-CHD: combinations of classical test theory and Generalizability theory  期刊论文  

  • 编号:
    5a77c5ee-27ef-4914-9f13-48e139b23405
  • 作者:
    Wan, Chonghua#*[1]Li, Hezhan#[1]Fan, Xuejin[2];Yang, Ruixue[3];Pan, Jiahua[4];Chen, Wenru[5];Zhao, Rong*[5,6]
  • 语种:
    英文
  • 期刊:
    HEALTH AND QUALITY OF LIFE OUTCOMES ISSN:1477-7525 2014 年 12 卷 ; JUN 4
  • 收录:
  • 关键词:
  • 摘要:

    Background: Quality of life (QOL) for patients with coronary heart disease (CHD) is now concerned worldwide with the specific instruments being seldom and no one developed by the modular approach.
    Objectives: This paper is aimed to develop the CHD scale of the system of Quality of Life Instruments for Chronic Diseases (QLICD-CHD) by the modular approach and validate it by both classical test theory and Generalizability Theory.
    Methods: The QLICD-CHD was developed based on programmed decision procedures with multiple nominal and focus group discussions, in-depth interview, pre-testing and quantitative statistical procedures. 146 inpatients with CHD were used to provide the data measuring QOL three times before and after treatments. The psychometric properties of the scale were evaluated with respect to validity, reliability and responsiveness employing correlation analysis, factor analyses, multi-trait scaling analysis, t-tests and also G studies and D studies of Genralizability Theory analysis.
    Results: Multi-trait scaling analysis, correlation and factor analyses confirmed good construct validity and criterion-related validity when using SF-36 as a criterion. The internal consistency a and test-retest reliability coefficients (Pearson r and Intra-class correlations ICC) for the overall instrument and all domains were higher than 0.70 and 0.80 respectively; The overall and all domains except for social domain had statistically significant changes after treatments with moderate effect size SRM (standardized response mea) ranging from 0.32 to 0.67. G-coefficients and index of dependability (phi coefficients) confirmed the reliability of the scale further with more exact variance components.
    Conclusions: The QLICD-CHD has good validity, reliability, and moderate responsiveness and some highlights, and can be used as the quality of life instrument for patients with CHD. However, in order to obtain better reliability, the numbers of items for social domain should be increased or the items' quality, not quantity, should be improved.

  • 推荐引用方式
    GB/T 7714:
    Wan Chonghua,Li Hezhan,Fan Xuejin, et al. Development and validation of the coronary heart disease scale under the system of quality of life instruments for chronic diseases QLICD-CHD: combinations of classical test theory and Generalizability theory [J].HEALTH AND QUALITY OF LIFE OUTCOMES,2014,12.
  • APA:
    Wan Chonghua,Li Hezhan,Fan Xuejin,Yang Ruixue,&Zhao Rong.(2014).Development and validation of the coronary heart disease scale under the system of quality of life instruments for chronic diseases QLICD-CHD: combinations of classical test theory and Generalizability theory .HEALTH AND QUALITY OF LIFE OUTCOMES,12.
  • MLA:
    Wan Chonghua, et al. "Development and validation of the coronary heart disease scale under the system of quality of life instruments for chronic diseases QLICD-CHD: combinations of classical test theory and Generalizability theory" .HEALTH AND QUALITY OF LIFE OUTCOMES 12(2014).
  • 条目包含文件:
    文件类型:PDF,文件大小:
    正在加载全文
浏览次数:55 下载次数:0
浏览次数:55
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部