首页 / 院系成果 / 成果详情页

Compound Doppler ultrasound signal simulation for pulsatile carotid arteries with a stenosis  期刊论文  

  • 编号:
    5dc96c65-2b7c-4226-a375-c79685e09d86
  • 作者:
    Gao, Lian#[1]Zhang, Yufeng*[1]Zhou, Yi[1];Hu, Xiao[1];Deng, Li[1];Zhang, Kexin[2];Cai, Guanghui[1];Zhang, Junhua[1];
  • 语种:
    英文
  • 期刊:
    BIO-MEDICAL MATERIALS AND ENGINEERING ISSN:0959-2989 2016 年 27 卷 2-3 期 (131 - 148)
  • 收录:
  • 关键词:
  • 摘要:

    BACKGROUND: The simulated Doppler blood flow signals are widely used to assess the performance of the clutter filters for removing wall components while reserving low-velocity signals scattered from physiological blood flow approaching the inner vessel-wall injured by a stenosed lesion.
    OBJECTIVE: By simultaneously taking into account the natural attributes of the Doppler equipment, blood flow as well as vessel wall of pulsatile carotid arteries with a stenosis, a computer simulation method is presented to produce the compound Doppler ultrasound blood flow signals.
    METHODS: The in-phase and quadrature (I/Q) axial as well as radial blood flow signals are simulated by superposing a series of cosine functions regulated by the spectrograms estimated from the axial and radial velocity profiles firstly obtained through the solution of the incompressible Navier-Stokes equations, respectively. Meanwhile, the I/Q Doppler signals echoed from pulsatile near (anterior) and far (posterior) walls are reproduced based on their radial movements during a cardiac cycle. Ultimately, those confirmed quadrature signals are summed to generate the compound Doppler signals including the contribution from both blood flow and stenosed vessel-wall.
    RESULTS: The compound Doppler ultrasound signals echoed from both axial and radial blood flows as well as vessel walls with obstruction grades of 0% (normal arteries), 10% and 25% are simulated respectively. The real signals from the left carotid artery with an approximately 10% stenosis degree are also collected for further assessing the believability of simulated versions.
    CONCLUSIONS: The simulated and clinical tests demonstrate that the proposed computer simulation method can produce compound Doppler signals with confirmed qualitative and quantitative characteristics resembled with the clinical versions, which could be used as an theoretical data source for evaluating the performance of the signal separation between pulsatile blood flows and vessel walls with mild stenosed-lesions.

  • 推荐引用方式
    GB/T 7714:
    Gao Lian,Zhang Yufeng,Zhou Yi, et al. Compound Doppler ultrasound signal simulation for pulsatile carotid arteries with a stenosis [J].BIO-MEDICAL MATERIALS AND ENGINEERING,2016,27(2-3):131-148.
  • APA:
    Gao Lian,Zhang Yufeng,Zhou Yi,Hu Xiao,&Zhang Junhua.(2016).Compound Doppler ultrasound signal simulation for pulsatile carotid arteries with a stenosis .BIO-MEDICAL MATERIALS AND ENGINEERING,27(2-3):131-148.
  • MLA:
    Gao Lian, et al. "Compound Doppler ultrasound signal simulation for pulsatile carotid arteries with a stenosis" .BIO-MEDICAL MATERIALS AND ENGINEERING 27,2-3(2016):131-148.
  • 条目包含文件:
    文件类型:PDF,文件大小:
    正在加载全文
浏览次数:62 下载次数:0
浏览次数:62
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部