Persistent Intraluminal Pressure After Endovascular Stent Grafting for Type B Aortic Dissection  期刊论文  

  • 编号:
    7d91399e-639c-4372-8aa9-3cc3eb0db8a6
  • 作者:
    Qing, K. X.(庆开雄)#[1]Chan, Y. C.[2];Ting, A. C. W.[2];Cheng, S. W. K.*[2]
  • 语种:
    英文
  • 期刊:
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY ISSN:1078-5884 2016 年 51 卷 5 期 (656 - 663) ; MAY
  • 收录:
  • 关键词:
  • 摘要:

    Objectives: Despite technically successful thoracic endovascular stent graft repair (TEVAR) in patients with Stanford Type B aortic dissection (TBAD), long-term follow up studies have shown that the false lumen may continue to dilate. The aim of this study was to analyze the possible mechanisms leading to such changes from a hemodynamic perspective.
    Methods: Twenty-eight ex vivo fresh porcine TBAD models (Mo A: 10; Model B: 12; Model C: 6) were established to simulate three clinical situations: Model A with patent false lumen (pre-TEVAR); Model B with distal re-entry only (post-TEVAR), and Model C with thrombus filling in the false lumen and a distal re-entry (chronic stage of post-TEVAR). Synchronous pressure waveforms were taken from both the true and the false lumen. True lumen and false lumen pressure differences were calculated for each model as four indices: systolic index (SI), diastolic index (DI), mean pressure index (MPI) and area under curve index (AUCI). These indices were compared between the three models.
    Results: False lumen pressure and corresponding pressure-accumulating effects were significantly higher in Model A than in Model C: SI (99.9% vs. 189.4%; p < .001); MPI and AUCI (99.5% vs. 128.2%; 99.5% vs. 128%; p < .001). The SI, MPI, and AUCI were significantly higher in Model B compared with Model C. The differences between the four indices were not significant between Model A and B. The false lumen area under curve (AUC) in Model C was merely lowered by 20% compared with its true lumen (67.5 mmHg vs. 85.2 mmHg).
    Conclusion: The false lumen pressure remained unchanged in the non-thrombosed segment with patent blood flow after the primary entry tear sealed. Intraluminal pressure reduction in the thrombosed false lumen was significant. However, nearly 80% of the pressure remained in the thrombosed false lumen. If this high intrathrombus pressure persists, it may contribute to delayed aneurysmal formation after endovascular treatment. (C) 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  • 推荐引用方式
    GB/T 7714:
    Qing K. -X.,Chan Y. -C.,Ting A. C. W., et al. Persistent Intraluminal Pressure After Endovascular Stent Grafting for Type B Aortic Dissection [J].EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY,2016,51(5):656-663.
  • APA:
    Qing K. -X.,Chan Y. -C.,Ting A. C. W.,Cheng S. W. K..(2016).Persistent Intraluminal Pressure After Endovascular Stent Grafting for Type B Aortic Dissection .EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY,51(5):656-663.
  • MLA:
    Qing K. -X., et al. "Persistent Intraluminal Pressure After Endovascular Stent Grafting for Type B Aortic Dissection" .EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY 51,5(2016):656-663.
  • 条目包含文件:
    文件类型:PDF,文件大小:
    正在加载全文
浏览次数:110 下载次数:0
浏览次数:110
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部