首页 / 院系成果 / 成果详情页

A comparative analysis of the effectiveness of active versus passive atrial lead fixation in Chinese patients with cardiac implantable electrical devices: a long term, retrospective, observational, single-center study  期刊论文  

  • 编号:
    c3f5c399-25f1-4a05-9ca0-2160a630c49f
  • 作者:
    Hao, Yinglu(郝应禄)#*; Li, Yanping;Liao, Derong;Yang, Ling;Liu, Fangyan;
  • 语种:
    英文
  • 期刊:
    CURRENT MEDICAL RESEARCH AND OPINION ISSN:0300-7995 2017 年 33 卷 3 期 (573 - 578) ; MAR
  • 收录:
  • 关键词:
  • 摘要:

    Background: Data comparing active atrial lead fixation with passive atrial lead fixation in Chinese patients with cardiovascular implantable electronic devices (CIEDs) for atrial pacing is limited. Our study evaluated the effectiveness of active fixation versus passive fixation of atrial leads by observing the lead performance parameters.
    Methods: This retrospective, long-term, single-center study included a cohort of Chinese patients who underwent CIED implantation at the Department of Cardiology of People's Hospital of Yuxi City, China, from 1 March 2010 to 1 March 2015. Efficacy was determined by comparing implantation time, threshold values, incidence of lead dislocation/failure, and lead-related complications between the two groups.
    Results: Of the 1217 patients, active and passive atrial lead fixation were performed in 530 (mean age, 69.37 +/- 11.44 years) and 497 (mean age, 68.33 +/- 10.96 years). The active fixation group reported significantly lower mean atrial implantation times (P=.0001) and threshold values (P=.044) compared with the passive atrial lead fixation group. In addition, threshold values in the active atrial lead fixation group were stable throughout the observation period. No instances of myocardial perforation, cardiac tamponade, implantation failure, or electrode dislocation/re-fixation were reported in the active atrial lead fixation group. A favorable decrease in patient comfort parameters such as bed rest time (P=.027) and duration of hospital stay (P=.038) were also observed in the active lead fixation group.
    Conclusion: Active atrial lead fixation demonstrated greater stability, steady long-term thresholds and minimal lead-related complications compared to passive lead fixation in Chinese patients with CIEDs.

  • 推荐引用方式
    GB/T 7714:
    Hao Yinglu,Li Yanping,Liao Derong, et al. A comparative analysis of the effectiveness of active versus passive atrial lead fixation in Chinese patients with cardiac implantable electrical devices: a long term, retrospective, observational, single-center study [J].CURRENT MEDICAL RESEARCH AND OPINION,2017,33(3):573-578.
  • APA:
    Hao Yinglu,Li Yanping,Liao Derong,Yang Ling,&Liu Fangyan.(2017).A comparative analysis of the effectiveness of active versus passive atrial lead fixation in Chinese patients with cardiac implantable electrical devices: a long term, retrospective, observational, single-center study .CURRENT MEDICAL RESEARCH AND OPINION,33(3):573-578.
  • MLA:
    Hao Yinglu, et al. "A comparative analysis of the effectiveness of active versus passive atrial lead fixation in Chinese patients with cardiac implantable electrical devices: a long term, retrospective, observational, single-center study" .CURRENT MEDICAL RESEARCH AND OPINION 33,3(2017):573-578.
  • 条目包含文件:
    文件类型:PDF,文件大小:
    正在加载全文
浏览次数:154 下载次数:0
浏览次数:154
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部